It is possible to activate the Do not disturbfunction on a Control Unit to disallow the
receipt of any kind of calls (see 4.2.4.C)
When this function is activated, the icon will appear in the display. Also, the
talk/auto-response process becomes talk only as it is no longer possible to receive
intercom calls (see 4.1.3.H. Intercom Call Permissions)
Even if the receipt of intercom calls
is cleared on a Control Unit, if the
Baby Monitor is activated at that time it can receive
the message in Baby Monitor operation .
IMPORTANT: Sensitivity levels 8 and 9 are for
extremely quiet areas. At those settings the voice
detector could become permanently activated due
to the background noise.
Key Sequence Display Visual
bla, bla...
See 4.2.4.F. Program menu:
Baby Monitor to program
Baby Monitor operation
ZONe 01
ZONe 09
m
4.2.3.F. “Do not disturb” function
4.1.3.G. A Control Unit's Neighbor Zones
2’’
If the Baby Monitor function has been activated successfully (that is, the
transmitting Control Unit has the required permissions and the receiving unit is
hooked up and can receive intercom calls) the icon will appear flashing. The
Control Unit accepts any form of operation: on, off, ...
When sound is detected in the room the Control Unit transmits an intercom
call without any key having been pressed. The intercom call will last as
long as the silence time programmed in the Baby Monitor settings.
Baby Monitor operation is compatible with the intercom call
operation mechanism described in section 4.1.3.A. and 4.1.3.B.,
that is, a call can be placed by pressing the key.
To end the operation, press the ON/OFF key from either
the transmitting or the receiving Control Unit.
If you wish to set the baby monitor receiver to do not
disturb, press the ON/OFF key for 2
m
Receiving zone information
Transmitting intercom calls
Transmitting intercom calls
The neighbor zonesfunction is available in Control Units that could
experience coupling in intercom calls because they are installed in the same room.
Although it is unlikely that intercom calls will be made between the units since they are in the same room, a general or group intercom call could be
made from either unit. The close proximity of the Control Units could cause coupling between the microphone of one unit and the loudspeaker of the
other.
To avoid this problem, each Control Unit has a set of zones called neighbor zonesfrom which it is not possible to receive intercom calls.
Programming and deleting “neighbor zones” in a Control Unit is only possible from the PC program.